| Product code |
EPBX14A9W + EPSK14AW1 | MHC-V16WD2RN7-B | HB-A160/CDS90GN8-B + MHA-V12W/D2RN8-B2 | 206678 + 207852 |
| Heating capacity Outdoor air +35°C/ 7°C |
14,85 kW | 16 kW | 12.1 kW | 3-16 kW |
| Product type |
Air-to-water heat pump | Air-to-water heat pump | Air-to-water heat pump | Air-to-water heat pump |
| Energy efficiency class (35°/55°) |
A+++ | A +++/ A+++ | A +++/ A++ | A+++/A++ |
| SCOP |
4.96 | 4.72 | 4.81 | 4.7 |
| Warranty |
2 years | 2 years | 2 years | 2 years |
| Estonian language menu |
Yes | | | |
| Wi-Fi smart remote control |
Yes | Yes | Yes | |
| Operating limit (Heating) |
-28 ~ 43 °C | -25 ~ 35 °C | -25 ~ 35 °C | -25 ~ +35 °C |
| Refrigerant |
R290 | R290 | R32 | R290 |
| Pipe size (Liquid/Gas) |
31.75 mm | | 9.52 + 15.9 mm | |
| Power supply voltage |
400/3/50 V/Ph/Hz | 380–415/3/50 V/Ph/Hz | 380/3/50 V/Ph/Hz | 400/3/50 V/Ph/Hz |
| Protection circuit breaker |
16 A | 16 A | 16 A | 16 A |
| Domestic hot water boiler capacity |
Separate | Separate | Separate | Separate |
| Maximum heating water temperature |
75 °C | 80 °C | 65 °C | 75 °C |
| Control and monitoring via the Internet |
| Yes | Yes | |
| Electric auxiliary heating element |
| 9 kW | 3+3+3 kW | |
| Maximum pipe length |
| | 30 m | |
| COP |
| | 4.95 | |
| Auxiliary heating element power |
| | 3+3+3 kW | |
| Active cooling option |
| | | Yes |
| Indoor unit weight |
34 kg | | 39 kg | 21 kg |
| Indoor unit dimensions (width x height x depth) |
440x840x390 mm | | 420×790×270 mm | |
| Indoor unit noise level |
31 dB(A) | | | |
| Outdoor unit weight |
191 kg | 169 kg | 112 kg | 140 kg |
| Outdoor unit dimensions (width x height x depth) |
1330x1123x604 mm | 1330x1051x475 mm | 1118x864x523 mm | 1270 x 1018 x 530 mm |
| Outdoor noise level |
38 dB(A) | 44 dB(A) | 50 dB(A) | 53 dB(A) |