| Product code |
EHVX04S18E6V + ERGA04EV | HB-A160/CDS90GN8-B + MHA-V16W/D2RN8-B2 | 526_358 | Flexit Nordic CL3 | FTXJ50AW + RXJ50A | HBT-A100/190CDS90GN8-B + MHA-V6W/D2N8-B2 |
| Heating capacity Outdoor air +35°C/ 7°C |
4.30 kW | 16.0 kW | 13.00 kW | | | 6.20 kW |
| Product type |
Air-to-water heat pump | Air-to-water heat pump | Air-to-water heat pump | Ventilation unit | Air conditioner | Air-to-water heat pump |
| Energy efficiency class (35°/55°) |
A+++ | A +++/ A++ | A++/A+ | | | A+++/A++ |
| SCOP |
4.48 | 4.62 | 4/3,02 | | 4.6 | 4.95 |
| Warranty |
2 years | 2 years | 5 years | | 2 years | 2 years |
| Estonian language menu |
Yes | | Yes | | Yes | |
| Wi-Fi smart remote control |
Yes | Yes | Yes | | Yes | Yes |
| Operating limit (Heating) |
-25 ~ 35 °C | -25 ~ 35 °C | -25 °C | | -20 ~ 24 °C | -25 ~ 35 °C |
| Refrigerant |
R32 | R32 | R410A | | R32 | R32 |
| Pipe size (Liquid/Gas) |
6.35 + 15.9 mm | 9.52 + 15.9 mm | 15,88/9,52 mm | | 6.35/12.7 mm | 6.35 + 15.9 mm |
| Power supply voltage |
230/1/50 V/Ph/Hz | 380/3/50 V/Ph/Hz | 400/3/50 V/Ph/Hz | 230 V/Ph/Hz | 1/50/220-240 V/Ph/Hz | 220-240/1/50 V/Ph/Hz |
| Protection circuit breaker |
16 A | 16 A | C16 A | 10 A | 13 A | 20 A |
| Control and monitoring via the Internet |
Yes | Yes | No | | | Yes |
| Domestic hot water boiler capacity |
180 l | Separate | 190 l | | | 190 l |
| Auxiliary heating element power |
2-4-6 kW | 3+3+3 kW | 3+3+3/9 kW | | | 3+3+3 kW |
| Maximum heating water temperature |
60 °C | 65 °C | 60 °C | | | 65 °C |
| Maximum pipe length |
| 30 m | 20 m | | 30 m | 30 m |
| COP |
| 4.50 | 4.18 | | | 5.00 |
| Electric auxiliary heating element |
| 3+3+3 kW | 3+3+3 kW | | | 3+3+3 kW |
| Active cooling option |
| | Yes | | | |
|
| | Clearance | | | |
|
| | #000000 | | | |
| Energy efficiency class |
| | | A | A++ | |
| Maximum air flow rate (100Pa) |
| | | 91 l/s or 328 m3/h | | |
| Approximate size of ventilated surface |
| | | 140 m² | | |
| Air duct connection |
| | | Ø 160 mm | | |
| Filters |
| | | 2 pieces ePM1 55% (F7) | | |
| Maximum power of the electric heater |
| | | 500 W | | |
| Nominal power, fans |
| | | 2 x 83 W | | |
| Type of heat exchanger |
| | | Rotor | | |
| Dimensions (width x height x depth) |
| | | 1160 x 700 x 296 mm | | |
| Returns moisture |
| | | Yes | | |
| Control via phone application |
| | | Yes | | |
| Required control panel |
| | | No | | |
| Required condensate drainage connection |
| | | No | | |
| Eurovent certificate (ensures data reliability) |
| | | Yes | | |
| Heating capacity (Min./Nom./Max.) |
| | | | 1.7/5.8/6.5 kW | |
| Cooling capacity (Min./Nom./Max.) |
| | | | 1.7/5.0/5.3 kW | |
| Color |
| | | | white | |
| Operating limit (Cooling) |
| | | | -10 ~ 50 °C | |
| Maximum height difference |
| | | | 20 m | |
| Nominal heating capacity |
| | | | 5.8 kW | |
| Nominal cooling capacity |
| | | | 5.0 kW | |
| SEER |
| | | | 8.74 | |
| Without exterior unit |
| | | | No | |
| Supports multiple indoor units |
| | | | No | |
| Indoor unit weight |
119 kg | 39 kg | 155/373 kg | | 12 kg | 140 kg |
| Indoor unit dimensions (width x height x depth) |
595x1650x625 mm | 420×790×270 mm | 648x1841x684 mm | | 305x900x212 mm | 600x1683x600 mm |
| Indoor unit noise level |
28 dB(A) | | 32 dB(A) | | 24/31/46 dB(A) | |
| Outdoor unit weight |
58.5 kg | 112 kg | 99 kg | | 49 kg | 60 kg |
| Outdoor unit dimensions (width x height x depth) |
884x740x388 mm | 1118x864x523 mm | 900x1290x400 mm | | 734x954x408 mm | 1007x712x426 mm |
| Outdoor noise level |
44 dB(A) | 55 dB(A) | 45 dB(A) | | 48 dB(A) | 45 dB(A) |