| Product code |
HBT-A160/240CDS90GN8-B + MHA-V12W/D2RN8-B2 | EX-12RE1N-I + EXH-12RE1N-O |
| Heating capacity Outdoor air +35°C/ 7°C |
12.1 kW | |
| Product type |
Air-to-water heat pump | Air-to-air heat pump |
| Energy efficiency class (35°/55°) |
A+++/A++ | |
| SCOP |
4.81 | |
| Warranty |
2 years | 2 years |
| Wi-Fi smart remote control |
Yes | Yes |
| Operating limit (Heating) |
-25 ~ 35 °C | -40 ~ 24 °C |
| Refrigerant |
R32 | R32 |
| Pipe size (Liquid/Gas) |
9.52 + 15.9 mm | 6.35/9.52 mm |
| Maximum pipe length |
30 m | 25 m |
| Power supply voltage |
380/3/50 V/Ph/Hz | 220-240/1/50 V/Ph/Hz |
| Protection circuit breaker |
16 A | 14 A |
| COP |
4.95 | |
| Control and monitoring via the Internet |
Yes | |
| Electric auxiliary heating element |
3+3+3 kW | |
| Domestic hot water boiler capacity |
240 l | |
| Auxiliary heating element power |
3+3+3 kW | |
| Maximum heating water temperature |
65 °C | |
| Heating capacity (Min./Nom./Max.) |
| 1.0/4.2/8.0 kW |
| Cooling capacity (Min./Nom./Max.) |
| 1.1/3.5/5.1 kW |
| Energy efficiency class |
| A+++ |
| Operating limit (Cooling) |
| -15 ~ 50 °C |
| Maximum height difference |
| 10 m |
| SCOP (Warm/medium/cold climate) |
| 5.1 |
| Indoor unit weight |
159 kg | 9.8 kg |
| Indoor unit dimensions (width x height x depth) |
600x1943x600 mm | 876x309x194 mm |
| Indoor unit noise level |
| 19/22/32/40/45 dB(A) |
| Outdoor unit weight |
100 kg | 43.5 kg |
| Outdoor unit dimensions (width x height x depth) |
1118x864x523 mm | 890x673x342 mm |
| Outdoor noise level |
50 dB(A) | 56 dB(A) |